Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses…

Read more

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel  Capacity:2 HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Combustion Air Fan…

Read more

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel  Capacity:2 HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Combustion Air Fan…

Read more

medical incinerators

medical incinerators are for pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies , Drug…

Read more

medical waste incinerator

medical waste incinerator is one type waste incinerator for hospital medical waste and the difference is the dual combustion chamber design to make…

Read more

china incinerator

the china incinerator is not mean low price, low quality now. hiclover design different model incinerator, 2 or 3 combustion chamber, smoke filter…

Read more

medical incinerator china

medical incinerator china ensure efficient, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red…

Read more